logo
products
PRODUCTS DETAILS
Home > Products >
Industrial Metal 10A 12V DIN Rail Power Supply AC/DC 120W For PLC

Industrial Metal 10A 12V DIN Rail Power Supply AC/DC 120W For PLC

MOQ: 10 pieces
Price: Negotiable
Standard Packaging: Paper box packing
Delivery Period: 5-8 working days
Payment Method: T/T,Western Union,MoneyGram
Supply Capacity: 10000 pieces per month
Detail Information
Place of Origin
Guangdong, China
Brand Name
KRONZ
Certification
CE
Model Number
PRF120-12A30
Product Name:
AC/DC 120W Din-rail Power Supply
Input:
AC/DC
Nominal Output:
12V/10A
Voltage Range:
11.8-14.0V
Max. Capacitive Load:
80000μF
Output Power:
120W
Leakage Current:
240VAC
Start Delay Time:
230VAC
Highlight:

12V Din Rail Power Supply

,

10A Din Rail Power Supply

,

DIN Rail Power Supply 120W

Product Description
Industrial Metal 10A 12V DIN Rail Power Supply AC/DC 120W For PLC
Product Attributes
Attribute Value
Product name AC/DC 120W Din-rail Power Supply
Input AC/DC
Nominal Output 12V/10A
Voltage Range 11.8-14.0V
Max. Capacitive Load 80000μF
Output Power 120W
Leakage Current 240VAC
Start Delay Time 230VAC
Product Description

Industrial Power Supply AC/DC 120W 12V/10A DIN-rail Metal for PLC

Industrial power supply 120W, 12V/10A provide customers with cost-effective, standard rail-mounted, efficient and energy-saving green power supplies. Provide high stability and high anti-interference power supply for industrial control equipment, machines and other industrial equipment in various harsh environments. The power supply is small in size, light in weight, compact in structure, and standard railmounted, saving customers a lot of space, the product is safe and reliable.

Features:
  • Input voltage: Universal 85 - 264VAC/120 - 370VDC
  • Accepts AC or DC Input (dual-use of same terminal)
  • Operating ambient temperature range: -40℃ to +70℃
  • High efficiency, high reliability
  • DC OK function
  • Active PFC
  • 150% peak power for 3 seconds of continuous output
  • Power supply start LED indicator light
  • Output short circuit, over-current, over-voltage, over-temperature protection
  • Satisfy 5000m altitude applications
  • Overvoltage level II
  • Indoor use
Selection Guide
Model No. Output Power Nominal Output Voltage & Current (Vo/lo) Output Voltage Adjustable Range (V) Efficiency at 230VAC (%) Typ. Max. Capacitive Load (μF)
PRF120-12A30 120 12V/10A 11.8-14.0 93.5 80000
Input Specifications
Item Operating Conditions Min. Typ. Max. Unit
Input Voltage Range Rated input (certified voltage) 100 -- 240 VAC
AC input 85 -- 264
DC input 120 -- 370 VDC
Input Voltage Frequency Rated AC input 50 -- 60 Hz
AC input 47 -- 63
Input Current Rated input -- -- 1.5 A
115VAC -- -- 1.5
230VAC -- -- 0.75
Inrush Current 115VAC Cold start -- 15 --
230VAC -- 30 --
Leakage Current 240VAC <1mA
Power Factor 115VAC -- 0.98 -- --
230VAC -- 0.94 --
Start Delay Time 230VAC -- 300 1000 ms
Hot Plug Unavailable
Output Specifications
Item Operating Conditions Min. Typ. Max. Unit
Output Voltage Accuracy Full load range -- ±1.0 -- %
Line Regulation Rated load -- ±0.5 --
Load Regulation 0% - 100% load -- ±1.0 --
Ripple & Noise 20MHz bandwidth (peak-peak value) 12V/24V -- 100 mv
48V/55V -- 120
Standby Power -- 2 -- W
Power-off retention time -- 20 -- ms
DC OK Function Resistive load 30VDC/1A Max.
Short Circuit Protection Recovery time < 10s after the short circuit disappear Hiccup mode,constant current works 1s,turn off 10s,continuous,self-recovery
Over-current Protection 230VAC,rated load Normal temperature, high temperature: 105%-200%lo,self recovery
Low temperature: ≥105% Full load after derating, self recovery
Over-voltage Protection 12V ≤18V | Hiccup, can self recover after the abnormal state is resolved
24V ≤35V
48V ≤60V
55V ≤63V
Over-temperature Protection 230VAC,70% load Over-temperature protection start -- 90 --
Over-temperature protection release 60 -- --
Note: The "tip and barrel method" is used for ripple and noise test, output parallel 47uF electrolytic capacitor and 0.1uF ceramic capacitor, please refer to Enclosed Switching Power Supply Application Notes for specific information;
*DC OK Signal: When the output voltage is normal, the relay is connected. When the output voltage is abnormal (<90%Vo), the relay is disconnected.
General Specifications
Item Operating Conditions Min. Typ. Max. Unit
Isolation Test Electric strength test for 1min, leakage current <15mA 1500 -- -- VAC
Input-Output 3000 -- --
Output- 500 -- --
Insulation Resistance Test voltage: 500VDC 50 -- --
Input-Output 50 -- --
Output- 50 -- --
Operating Temperature -40 -- +70
Storage Temperature -40 -- +85
Storage Humidity Non-condensing -- -- 95 %RH
Operating Humidity 20 -- 95
Switching Frequency -- 100 -- kHz
Output Power Derating Operating temperature derating -40℃ to -25 ℃ 3.34 -- %℃
+55℃ to +70 ℃ 85VAC-164VAC 2.0 --
+60℃ to +70 ℃ 165VAC-264VAC 3.0 --
Input voltage derating 85VAC-100VAC 0.67 -- -- %VAC
Safety Standards 12V/24V/48V55V UL61010-1,UL61010-2-201 safety approved & EN62368-1 Comform to IEC/UL/BS EN 62368-1
55V Conform to IEC/EN/UL/BS EN 62368-1,UL61010-1,UL61010-2-201
Safety Class CLASS I
MTBF MIL-HDBK-217F@25℃ >300,000 h
Physical Characteristics
Item Specification
Case Material Metal (AL5052,SPCC,SGCC)
Dimensions 110.00 x 32.00 x 124.00 mm
Weight 490g ±1% (Typ.)
Cooling Method Free air convection
EMC Characteristics
Type Standard Performance
EMI CE | CISPR32/EN55032 CLASS B
RE CISPR32/EN55032 CLASS B
Harmonic current IEC/EN 61000-3-2 CLASS A and CLASS D
EMS ESD | IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV perf. Criteria A
PS | IEC/EN 61000-4-3 10V/m perf. Criteria A
EFT | IEC/EN 61000-4-4 ±4KV perf. Criteria A
Surge | IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV perf. Criteria A
CS | IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A
Voltage dips, short interruptions and voltage variations immunity | IEC/EN61000-4-11 0%, 70% perf. Criteria A
Company Profile
products
PRODUCTS DETAILS
Industrial Metal 10A 12V DIN Rail Power Supply AC/DC 120W For PLC
MOQ: 10 pieces
Price: Negotiable
Standard Packaging: Paper box packing
Delivery Period: 5-8 working days
Payment Method: T/T,Western Union,MoneyGram
Supply Capacity: 10000 pieces per month
Detail Information
Place of Origin
Guangdong, China
Brand Name
KRONZ
Certification
CE
Model Number
PRF120-12A30
Product Name:
AC/DC 120W Din-rail Power Supply
Input:
AC/DC
Nominal Output:
12V/10A
Voltage Range:
11.8-14.0V
Max. Capacitive Load:
80000μF
Output Power:
120W
Leakage Current:
240VAC
Start Delay Time:
230VAC
Minimum Order Quantity:
10 pieces
Price:
Negotiable
Packaging Details:
Paper box packing
Delivery Time:
5-8 working days
Payment Terms:
T/T,Western Union,MoneyGram
Supply Ability:
10000 pieces per month
Highlight

12V Din Rail Power Supply

,

10A Din Rail Power Supply

,

DIN Rail Power Supply 120W

Product Description
Industrial Metal 10A 12V DIN Rail Power Supply AC/DC 120W For PLC
Product Attributes
Attribute Value
Product name AC/DC 120W Din-rail Power Supply
Input AC/DC
Nominal Output 12V/10A
Voltage Range 11.8-14.0V
Max. Capacitive Load 80000μF
Output Power 120W
Leakage Current 240VAC
Start Delay Time 230VAC
Product Description

Industrial Power Supply AC/DC 120W 12V/10A DIN-rail Metal for PLC

Industrial power supply 120W, 12V/10A provide customers with cost-effective, standard rail-mounted, efficient and energy-saving green power supplies. Provide high stability and high anti-interference power supply for industrial control equipment, machines and other industrial equipment in various harsh environments. The power supply is small in size, light in weight, compact in structure, and standard railmounted, saving customers a lot of space, the product is safe and reliable.

Features:
  • Input voltage: Universal 85 - 264VAC/120 - 370VDC
  • Accepts AC or DC Input (dual-use of same terminal)
  • Operating ambient temperature range: -40℃ to +70℃
  • High efficiency, high reliability
  • DC OK function
  • Active PFC
  • 150% peak power for 3 seconds of continuous output
  • Power supply start LED indicator light
  • Output short circuit, over-current, over-voltage, over-temperature protection
  • Satisfy 5000m altitude applications
  • Overvoltage level II
  • Indoor use
Selection Guide
Model No. Output Power Nominal Output Voltage & Current (Vo/lo) Output Voltage Adjustable Range (V) Efficiency at 230VAC (%) Typ. Max. Capacitive Load (μF)
PRF120-12A30 120 12V/10A 11.8-14.0 93.5 80000
Input Specifications
Item Operating Conditions Min. Typ. Max. Unit
Input Voltage Range Rated input (certified voltage) 100 -- 240 VAC
AC input 85 -- 264
DC input 120 -- 370 VDC
Input Voltage Frequency Rated AC input 50 -- 60 Hz
AC input 47 -- 63
Input Current Rated input -- -- 1.5 A
115VAC -- -- 1.5
230VAC -- -- 0.75
Inrush Current 115VAC Cold start -- 15 --
230VAC -- 30 --
Leakage Current 240VAC <1mA
Power Factor 115VAC -- 0.98 -- --
230VAC -- 0.94 --
Start Delay Time 230VAC -- 300 1000 ms
Hot Plug Unavailable
Output Specifications
Item Operating Conditions Min. Typ. Max. Unit
Output Voltage Accuracy Full load range -- ±1.0 -- %
Line Regulation Rated load -- ±0.5 --
Load Regulation 0% - 100% load -- ±1.0 --
Ripple & Noise 20MHz bandwidth (peak-peak value) 12V/24V -- 100 mv
48V/55V -- 120
Standby Power -- 2 -- W
Power-off retention time -- 20 -- ms
DC OK Function Resistive load 30VDC/1A Max.
Short Circuit Protection Recovery time < 10s after the short circuit disappear Hiccup mode,constant current works 1s,turn off 10s,continuous,self-recovery
Over-current Protection 230VAC,rated load Normal temperature, high temperature: 105%-200%lo,self recovery
Low temperature: ≥105% Full load after derating, self recovery
Over-voltage Protection 12V ≤18V | Hiccup, can self recover after the abnormal state is resolved
24V ≤35V
48V ≤60V
55V ≤63V
Over-temperature Protection 230VAC,70% load Over-temperature protection start -- 90 --
Over-temperature protection release 60 -- --
Note: The "tip and barrel method" is used for ripple and noise test, output parallel 47uF electrolytic capacitor and 0.1uF ceramic capacitor, please refer to Enclosed Switching Power Supply Application Notes for specific information;
*DC OK Signal: When the output voltage is normal, the relay is connected. When the output voltage is abnormal (<90%Vo), the relay is disconnected.
General Specifications
Item Operating Conditions Min. Typ. Max. Unit
Isolation Test Electric strength test for 1min, leakage current <15mA 1500 -- -- VAC
Input-Output 3000 -- --
Output- 500 -- --
Insulation Resistance Test voltage: 500VDC 50 -- --
Input-Output 50 -- --
Output- 50 -- --
Operating Temperature -40 -- +70
Storage Temperature -40 -- +85
Storage Humidity Non-condensing -- -- 95 %RH
Operating Humidity 20 -- 95
Switching Frequency -- 100 -- kHz
Output Power Derating Operating temperature derating -40℃ to -25 ℃ 3.34 -- %℃
+55℃ to +70 ℃ 85VAC-164VAC 2.0 --
+60℃ to +70 ℃ 165VAC-264VAC 3.0 --
Input voltage derating 85VAC-100VAC 0.67 -- -- %VAC
Safety Standards 12V/24V/48V55V UL61010-1,UL61010-2-201 safety approved & EN62368-1 Comform to IEC/UL/BS EN 62368-1
55V Conform to IEC/EN/UL/BS EN 62368-1,UL61010-1,UL61010-2-201
Safety Class CLASS I
MTBF MIL-HDBK-217F@25℃ >300,000 h
Physical Characteristics
Item Specification
Case Material Metal (AL5052,SPCC,SGCC)
Dimensions 110.00 x 32.00 x 124.00 mm
Weight 490g ±1% (Typ.)
Cooling Method Free air convection
EMC Characteristics
Type Standard Performance
EMI CE | CISPR32/EN55032 CLASS B
RE CISPR32/EN55032 CLASS B
Harmonic current IEC/EN 61000-3-2 CLASS A and CLASS D
EMS ESD | IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV perf. Criteria A
PS | IEC/EN 61000-4-3 10V/m perf. Criteria A
EFT | IEC/EN 61000-4-4 ±4KV perf. Criteria A
Surge | IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV perf. Criteria A
CS | IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A
Voltage dips, short interruptions and voltage variations immunity | IEC/EN61000-4-11 0%, 70% perf. Criteria A
Company Profile